Scans
Start a scan
New scan is the green button at the top of the rail. It takes you from an application to a running scan on one page. This page explains every option on it. For the shortest path with the defaults, see Your first scan.
In the dashboard: ScansNew scan
Open New scan (opens in a new tab)Pick or add an application
Section titled “Pick or add an application”Select New scan. The page lists your applications, the most recently scanned first, with each one’s last completed scan and login state.
- Find an application. Type part of its name in Find an application or paste a URL, then select it. Use the arrow keys and Enter if you prefer the keyboard.
- Paste a URL. NightVision offers to add it as a new web application. A URL that ends in
.json,.yamlor.ymlis offered as a new API application built from that spec. - Drop a spec file on the page to add an API application from an OpenAPI spec or a Postman collection.
- Add a new application. Select Web app or API to open the New application form. See Applications.
After you pick or add an application, the page becomes Scan followed by the application’s name, with the settings below. Select Change to go back and pick another application.
Applications in a project where your role cannot start scans show You cannot scan in this project.

Authentication
Section titled “Authentication”Authentication is how the scan signs in. The menu lists the authentications in the application’s project, each with its kind.
- NightVision preselects the authentication the last scan of this application used. If there is none, it preselects the one assigned to the application.
- Select No authentication to scan as an anonymous visitor. The scan then reaches only what is public.
- Select Add authentication to create one without leaving the page. See Authentication.
If the last login with the selected authentication failed, the page says so and links to Re-record it.
Re-authenticate before the active scan appears for a recorded login. It signs in again before the active checks start, so a long scan does not test with an expired session. It is on by default for scans of 2 hours or more.
Scan duration
Section titled “Scan duration”Scan duration is the longest the scan may run: 30 min, 1 hour, 2 hours, 4 hours or 8 hours. A scan that finishes its work earlier ends earlier. A scan that reaches the limit stops and is marked Timed out, and it keeps the findings it reported.
The default is 30 minutes. If the application has been scanned before, the page starts from the last scan’s duration and says From the last scan.
Pick a longer duration for a large web application. Coverage tells you afterward whether the scan hit its time limit and what it had not reached.
Scans of 2 hours or more unlock options for web applications:
- Enable intelligent page load handling waits until each page has finished loading instead of using fixed delays. It is on by default.
- Use LLM-based crawling lets the crawler explore the application more like a person would. It appears when LLM crawling is turned on for your organization and needs your organization’s OpenAI key.
- Network analysis, when it is turned on for the application, records which API calls each screen makes.
These are explained in Crawler settings.
Where it runs: NightVision Cloud or your network
Section titled “Where it runs: NightVision Cloud or your network”- NightVision Cloud runs the scan from NightVision. Use it for any application that is reachable from the internet.
- CLI helper (private network) is for applications that are not reachable from the internet. It gives you a command to run on a machine in your network.
When the application is marked private, the CLI helper is selected for you and NightVision Cloud is unavailable.
With the CLI helper selected, the button reads Generate command. Select it to get the command:

- Choose macOS and Linux or Windows PowerShell.
- Copy the command and paste it on a machine that can reach the application. The machine needs the NightVision CLI.
- Select I started the scan to go to the Scans page, where the run appears.
If you edited the exclusions, the panel shows two commands: Apply the exclusions first, then Run the scan.
Three options are not available with the CLI helper: schedules, the leaked credential check, and the custom template list. See Scan private networks for how the connection works.
Leaked credentials
Section titled “Leaked credentials”The Leaked credential check switch replays breached credentials for this application through the recorded login and reports any that still work. It is off by default. See Leaked credential check.
Choose checks
Section titled “Choose checks”Every check runs unless you turn it off. To change that, open Advanced and go to Checks. A switch or box that is on means that check runs.

Active and passive checks (ZAP) are the scanner’s own checks, such as SQL Injection and Cross Site Scripting. Turn the switch off to skip all of them, or untick single checks. Use Filter checks to find one by name.
Nuclei templates look for known vulnerabilities, exposures and misconfigurations.

- Public and built-in Nuclei templates are grouped in folders, such as
http/cvesandhttp/misconfiguration. NightVision built-in templates are the ones NightVision maintains. Untick a folder to skip it. - Custom Nuclei templates are the templates you assigned to this application. Untick one to skip it for this scan. See Nuclei templates.
- Run only custom templates turns ZAP and every built-in folder off and keeps your custom templates on. Use it to test one template quickly.
At least one set of checks must stay on. If nothing would run, the page tells you and Start scan stays disabled.
NightVision also skips checks that cannot apply to the technology an application runs. For example, Java-only checks do not run against an application whose responses show another stack. You do not need to turn these off yourself.
What you choose here applies to this scan only. The run’s Scan parameters record which checks were off. See Read a scan.
Exclusions
Section titled “Exclusions”Advanced also holds the application’s exclusions:
- Exclusions are URL patterns the scan skips, one per line.
- Exclude clicks based on XPath lists elements the crawler never clicks, one per line, such as a logout button. Web applications only.
If a pattern matches the application’s own address, the scan would skip everything. The page warns you and offers to remove the pattern. See Scope and exclusions.
Schedule instead of start
Section titled “Schedule instead of start”To repeat the scan instead of running it once now:
- Open Schedule and turn on Repeat this scan on a schedule.
- In the Scan planner, choose the period, the day and the time, then select Use this schedule.
- Select Schedule scan.

A scheduled scan does not run now. It first runs at the time you chose, and each run uses the settings on this page. Private applications cannot be scheduled. See Schedule scans.
Start the scan
Section titled “Start the scan”Select Start scan, or press Cmd+Enter on macOS or Ctrl+Enter on Windows and Linux. The run opens on its Findings tab, and findings appear as the scan reports them. See Read a scan.
If the dashboard cannot confirm that the scan started, for example after a network error, it shows View scans instead of offering a second start. Check the Scans page before you start another one, so the application is not scanned twice.
From the CLI and CI
Section titled “From the CLI and CI”The CLI starts the same scan. The CLI and the API call an application a target.
nightvision scan my-app \ --project my-project \ --auth my-login \ --max-duration-minutes 120| Flag | What it does |
|---|---|
-p, --project |
The name of the project the application is in. |
-P, --project-id |
The project’s ID, instead of its name. |
-c, --auth |
The name of the authentication to sign in with. |
-C, --auth-id |
The authentication’s ID, instead of its name. |
--no-auth |
Run the scan without an authentication. |
--max-duration-minutes |
The scan duration in minutes, from 30 to 480. The default is 30. |
--no-zap |
Turn off the active and passive checks. |
--no-nuclei |
Turn off Nuclei templates. At least one of the two must stay on. |
--disable-zap-active-alerts |
A comma-separated list of check IDs to skip. |
--disable-nuclei-folders |
A comma-separated list of Nuclei folders to skip. |
--disable-nuclei-templates |
A comma-separated list of the application’s custom template IDs to skip. |
--no-intelligent-page-load-handling |
Turn off intelligent page load handling. |
--login-check |
Run only the login and report whether it works. See Login check. |
In a pipeline, set a NIGHTVISION_TOKEN secret and run the same command. See Integrations for ready-made pipeline examples and CLI commands for the full reference.
When Start is disabled
Section titled “When Start is disabled”The page says why next to the button or the field that needs attention.
| What you see | What to do |
|---|---|
| Your role does not allow starting scans in this project. | Ask an Org Admin or the project’s owner for access, or choose another application. See Members and roles. |
| Your trial has used all its scans. Upgrade to run more. | Upgrade the plan. A rescan counts as a scan too, so it is blocked as well. A login check does not count. See Settings. |
| Your organization’s plan does not include this. | Ask an Org Admin about the plan. |
| A message about the specification, such as Validating the specification or The specification is not valid | An API scan waits for its spec. If the spec is not valid, open the application and fix it. See API specs. |
| At least one set of checks must stay on, or Nothing would run | Open Advanced and turn a set of checks back on. |
| A message under the leaked credential fields | Fill in the validation settings, or turn the check off. |
| This authentication has a scan still finishing. | A scan that uses the same MFA login is still starting. Wait the number of seconds shown and try again. |